Details:
First, the technical parameters
1, the scope of the pilot flow: 5L/min ~ 50L/min
2, flow rate accuracy: 1
3, control range: room temperature ~ 100 ℃
4, the pressure accuracy: 0.5
5, fuel tanks: stainless steel, with a capacity of about 50L
6, Motor Power: 3.7kw
7, power supply voltage: 380V/50Hz
8, Machine Weight: 500kg
9, size: 1610 × 870 × 1470mm (L × W × H)
Second, the main characteristics of
1, the use of high-precision determination of an oval gear flow meter to test the flow.
2, this machine can be measured with precision test pressure gauge out of the oil pressure.
3, test-bed work tops stainless steel plate, pipe and fittings are rust-proof material.
4, impurities can add devices uniform mixing of impurities in order to test the plug filter life.
5, in line with the test method: JB/T6725-93, ISO4548.
Third, the scope of application
The test bed can be detected: the pressure drop / flow characteristics, characteristics of bypass components, open the bypass valve pressure plug filter life, filter-resistant high-pressure drop, high temperature resistance and other tests.